More than 100 years committed to technical progress has made us the leading manufacturer in the fields of variable AC drives, servo drives, control technology and robotics.
U1000 Series
CIMR-UC4E0040AAA
Low Harmonics Regenerative Matrix Converter
Yaskawa Europe Products AC Drives Regenerative Solutions U1000 Series CIMR-UC4E0040AAA
Overview
U1000 is the perfect match for single motor drive applications with requirements to power regeneration and low harmonics such as lifts, escalators, HVAC machinery, hoists, centrifuges, and many others.
U1000 is approved for global marine installation. Compared to 12 pulse systems the Yaskawa matrix design provides significant footprint and weight savings, keeping the THDi within the IEEE 519 limits.
- Precise control of induction and permanent motors with or without encoder
- Highly efficient AC to AC direct conversion
- Automatic motor data adjustment
- 13 language full text keypad built in
Technical Details
- Input power supply
- 400 V
- Rated output current (HD)
- 34 A
- Rated output current (ND)
- 40 A
- 50% ED Rated Output Current
- x No
- Overload Tolerance (ND)
- 120 % for 60 s
- Overload Tolerance (HD)
- 150 % for 60 s
- Max. applicable motor power (HD)
- 15 kW
- Max. applicable motor power (ND)
- 18.5 kW
- Input power phases
- 3-phase
- EMC filter
- ✓ Yes
- Motor type
- Permanent magnet motor, Induction motor
- Encoder
- x No
- Standards compliance
- CE, RoHS, UL, GL, UKCA
- Regenerative Capacity
- x No
- Ambient Temperature (Min)
- -10 °C
- Ambient Temperature (Max)
- 40 °C
- Ambient Temperature (Max) with Derating
- 50 °C
- Max. Humidity (non-condensing)
- 95 %
- Max. Altitude (without Derating)
- 1000 m
- Max. Altitude (with Derating)
- 3000 m
- Height
- 650 mm
- Width
- 264 mm
- Depth
- 420 mm
- Weight
- 33 kg
- Cooling method
- Air cooling
- Enclosure
- IP00
- Environmental Specifications
- Standard
- Analog Input
- 3
- Analog Output
- 2
- Digital Input
- 8
- Digital Output
- 4
- Safety Level
- SIL3
- Performance Level
- PL e
- Torque Control
- Standard
- Braking transistor
- External
- Motor Thermal Protection
- Standard
- Max Output Frequency
- 400 Hz
Downloads
Name | |||
U1000 Low Harmonics Regenerative Matrix Converter
Brochure No. YEU_INV_U1000_EN_v3 Brochures | English |
Brochures | English | |
U1000 Low Harmonics Regenerative Matrix Converter
Brochure No. YEU_INV_U1000_DE_v3 Brochures | German |
Brochures | German | |
U1000 Low Harmonics Regenerative Matrix Converter
Brochure No. YEU_INV_U1000_FR_v3 Brochures | French |
Brochures | French | |
U1000 Low Harmonics Regenerative Matrix Converter
Brochure No. YEU_INV_U1000_IT_v3 Brochures | Italian |
Brochures | Italian | |
U1000 Low Harmonics Regenerative Matrix Converter
Brochure No. YEU_INV_U1000_PL_v3 Brochures | Polish |
Brochures | Polish | |
U1000 for Installations on Ships and Offshore
Flyer No. YEU_INV_U1000_Marine_Flyer_EN_ v1 Brochures | English |
Brochures | English | |
U1000 | Technical Manual
SIEP-C710636-03E Technical documentation | English |
Technical documentation | English | |
U1000 | Technical Manual
SIGP-C710636-03A Technical documentation | German |
Technical documentation | German | |
U1000 | Quick-Start-Guide
TOEP-C710636-03C Technical documentation | English |
Technical documentation | English | |
U1000 AC Drives | EU Declaration of Conformity
Low Voltage Directive, Electromagnetic Compatibility Directive, Machine Directive, RoHS, Certificate No. EZZ024525<2> issued August 5, 2024 Certification | Czech, Danish, Dutch, English, Finnish, French, German, Italian, Polish, Slovenian, Spanish, Swedish |
Certification | Czech, Danish, Dutch, English, Finnish, French, German, Italian, Polish, Slovenian, Spanish, Swedish | |
U1000 TÜV Certificate
TÜV Certification AC Drive Serie U1000, EN-ISO 13849-1/AC:2008 IEC 61508-1:2010 (SIL 3) IEC 61508-2:2010 (SIL 3) IEC 61508-4:2010) (SIL 3) EN 61508-1:2010 (SIL 3) EN 61508-2:2010 (SIL 3) EN 61508-4:2010 (SIL 3) IEC 62061/A1:2012 (SIL CL 3) EN 62061/A1:2013 (SIL CL 3) IEC 61800-5-2;2007 (SIL 3) EN 61800-5-2;2007 (SIL 3) IEC 61800-5-1;2007 EN 61800-5-1;2007 date of issue 2021-02-15 Certification | English |
Certification | English | |
EPLAN for Regenerative Matrix Converter U1000
EPLAN Makros for U1000 Models with built-in EMC Filter, Data package includes all modells EPLAN | English |
EPLAN | English | |
PG-B3 Complementary PG Option for AC Drives | Installation Manual
TOBP-C730600-36D Technical documentation | English |
Technical documentation | English | |
PG-X3 Line Driver Type PG Option for AC Drives | Installation Manual
TOBP-C730600-37C Technical documentation | English |
Technical documentation | English | |
PG-F3 Motor Encoder Feedback Interface Option for AC Drives | Installation Manual
EnDat, HIPERFACE, TOBP-C730600-77C, formerly TOBP-C730600-51 Technical documentation | English |
Technical documentation | English | |
PG-RT3 Resolver Interface Option for AC Drives | Installation Manual
Spec. TS2640N321E64, TOBP-C730600-53B Technical documentation | English |
Technical documentation | English | |
2D CAD for U1000 Matrix Converter [4x0040]
Model CIMR-UC4A0040AAA, CIMR-UC4E0040AAA CAD/CAE | |
CAD/CAE | ||
3D CAD for U1000 Matrix Converter [4x0040]
Model CIMR-UC4A0040AAA, CIMR-UC4E0040AAA CAD/CAE | |
CAD/CAE | ||
U1000 AC Drives | ABS Certificate
Certificate number 21-2192273 -PDA Certification | English |
Certification | English | |
U1000 AC Drives | BV Certificate
Certificate number 52006/B0 BV Certification | English |
Certification | English | |
U1000 AC Drives | DNV Certificate
Certificate number TAE00002A7 Certification | English |
Certification | English | |
U1000 AC Drives | KR Certificate
Certificate number TKY38568-AC001 Certification | |
Certification | ||
U1000 AC Drives | LR Certificate
Certificate number LR22423040TA Certification | English |
Certification | English | |
U1000 AC Drives | NK Certificate
Certificate number TA22674M Certification | English |
Certification | English | |
U1000/U1000L AC Drives | UKCA Declaration of Conformity
EZZ024548 issued August 16, 2022 Certification | English |
Certification | English |