CP 040 - Communication Processor - 040-1CA00
Ordercode: 040-1CA00
- RS422/485 interface
- Protocols ASCII, STX/ETX, 3964(R) and Modbus RTU (master, slave)
Technical Details
- Input power supply
- x No
- Input Voltage
- x No
- Current Consumption
- x No
- Max. current drain at backplane bus
- x No
- Max. current drain load supply
- x No
- Current consumption from backplane bus
- 125 mA
- Current consumption from load voltage L+ (without load)
- 10 mA
- Power Loss
- 1 W
- Number of inputs (digital)
- x No
- Rated load voltage (digital)
- x No
- Current consumption from load voltage L+ (without load)
- x No
- Signal logic input (digital)
- x No
- Input characteristic curve (digital)
- x No
- Initial data size (digital)
- x No
- Number of outputs (digital)
- x No
- Rated load voltage (digital output)
- x No
- Current consumption from load voltage L+ (without load)
- x No
- Signal logic output (digital)
- x No
- Output data size (digital)
- x No
- Number of inputs (analog)
- x No
- Rated load voltage (analog)
- x No
- Current consumption from load voltage L+ (without load)
- x No
- Voltage inputs (analog)
- x No
- Current inputs (analog)
- x No
- Resolution in bit
- x No
- Measurement principle
- x No
- Basic conversion time
- x No
- Initial data size
- x No
- Number of outputs (analog)
- x No
- Output voltage ranges
- x No
- Output current ranges
- x No
- Resolution in bit (analog)
- x No
- Conversion time (analog)
- x No
- Output data size (analog)
- x No
- Number of counters
- x No
- Counter width
- x No
- Maximum input frequency
- x No
- Maximum count frequency
- x No
- Maximum count frequency
- x No
- Maximum count frequency
- x No
- Maximum count frequency
- x No
- Number of channels
- x No
- Input voltage (rated value)
- x No
- Power stage
- x No
- PWM frequency
- x No
- Type of encoder
- x No
- Encoder frequency
- x No
- Encoder resolution (internal)
- x No
- Control type
- x No
- Terminal voltage max.
- x No
- Terminal current max.
- x No
- Total current per module, max.
- x No
- Number of clamps
- x No
- Binding of potential
- x No
- Point-to-point protocol
- ASCII protocol, STX/ETX protocol, 3964(R) protocol, Modbus master protocol, Modbus slave protocol
- Encoder Supply: Number of outputs (L+n)
- x No
- Rated output current
- x No
- Port mode
- x No
- Load memory, integrated
- x No
- Work memory, integrated
- x No
- Work memory, maximal
- x No
- Memory card slot
- x No
- Racks, max.
- x No
- Modules per rack, max.
- x No
- Fieldbus
- x No
- Connector
- x No
- Topology
- x No
- Transmission speed, max.
- x No
- Address range inputs, max.
- x No
- Address range outputs, max.
- x No
- Material
- PPE / PPE GF10
- Mounting
- Profile rail 35 mm
- Weight
- 12.9 mm
- Height
- 109 mm
- Depth
- 76.5 mm
- Net weight
- 59 g
- Gross weight
- 74 g
- Certifications
- UL certification, KC certification, UKCA certification, ChinaRoHS certification
- Safety protocol
- x No
- Safety requirements
- x No
- Circuit monitoring
- x No
- Max. operating temperature
- 60 °C
Downloads
Name | |||
CP 040 - Communication Processor - 040-1CA00
Datasheet for SLIO Communication Processor 040-1CA00 Data sheet | English |
Data sheet | English | |
CP 040 - Kommunikationsprozessor - 040-1CA00
Datenblatt für SLIO Kommunikationsprozessor 040-1CA00 Data sheet | German |
Data sheet | German | |
CP 040-1CA00 - Communication processor
Rev. 24-04 || SLIO CP 040-1CA00 (RS422/485) || HW: 01 | CP-FW: V1.0.1 Technical documentation | English |
Technical documentation | English | |
CP 040-1CA00 - Kommunikationsprozessor
Rev. 24-04 || SLIO CP 040-1CA00 (RS422/485) || HW: 01 | CP-FW: V1.0.1 Technical documentation | German |
Technical documentation | German | |
System guide - Industrial IT Security
Rev. 21-12 || Guide Industrial Security in Information Technology Technical documentation | English |
Technical documentation | English | |
Systemleitfaden - Industrielle IT-Sicherheit
Rev. 21-12 || Leitfaden Industrielle Sicherheit in der Informationstechnologie Technical documentation | German |
Technical documentation | German | |
System SLIO - Liste der Stromaufnahmen
Rev. 24-36 || SLIO Liste der Stromaufnahmen der System SLIO Module Technical documentation | German |
Technical documentation | German | |
System SLIO - List of current consumptions
Rev. 24-36 || SLIO List of the current consumptions of the System SLIO modules Technical documentation | English |
Technical documentation | English | |
System SLIO - Kompatibilitätsliste
Rev. 24-25 || SLIO System SLIO CPUs, System SLIO IMs, Taktsynchronität Technical documentation | German |
Technical documentation | German | |
System SLIO - Compatibility list
Rev. 24-25 || SLIO System SLIO CPUs, System SLIO IMs, Isochronous mode Technical documentation | English |
Technical documentation | English | |
EU-Declaration of Conformity - SLIO
state: 03.03.2020 Certification | German, English |
Certification | German, English | |
UL SLIO
Vol1 Sec2 Certification | English |
Certification | English | |
UK-Declaration of Conformity - SLIO
state: 10.09.2024 Certification | English |
Certification | English | |
EU-Declaration of Conformity - SLIO
state: 10.09.2024 Certification | English, German |
Certification | English, German | |
YASKAWA Controls MTBF Technical documentation | English | Technical documentation | English | |
3D-Data SLIO Module 8x
SLIO Module 8 contact points / SLIO Module 8 point terminal CAD/CAE | English, German |
CAD/CAE | English, German | |
Yaskawa System Slio | ChinaRoHS Certification | | Certification | ||
SLIO Labeling Stripes
To print approximately the same labeling stripes as the original, it is best to use chromosulphate board with 300g sheet weight. Technical documentation | English |
Technical documentation | English | |
System SLIO Ersatzteile Technical documentation | German | Technical documentation | German | |
System SLIO Spare Parts Technical documentation | English | Technical documentation | English | |
SLIO - Das dezentrale I/O-System
SLIO (= Sliced I/O) ist ein modular aufgebautes und kompaktes, dezentrales I/O-System. Brochures | German |
Brochures | German | |
SLIO - The decentralized I/O system
SLIO (= sliced I/O) is a modular and extremely compact, decentralized I/O system. Brochures | English |
Brochures | English |