More than 100 years committed to technical progress has made us the leading manufacturer in the fields of variable AC drives, servo drives, control technology and robotics.
D1000 Series
CIMR-DC4A0270AAA
Regenerative Converter Unit
Yaskawa Europe Products AC Drives Regenerative Solutions D1000 Series CIMR-DC4A0270AAA
Overview
The Yaskawa D1000 regenerative converter unit saves energy and space. Suitable for both regenerative individual drives and systems of AC drives, servo axes or robots, the D1000 feeds excess braking energy back into the grid instead of converting it into heat. This not only reduces energy consumption and cost but also contributes to the protection of our environment.
- Low energy consumption due to common DC bus systems – the braking energy of one drive is consumed by other drives in the system
- Sinusoidal input current reduces the strain on the power supply system (lines, transformers)
- Less installation space as braking transistors and resistors are not required
- Lowers the total operating costs of the system
Technical Details
- Input power supply
- 400 V
- Rated output current (HD)
- x No
- Rated output current (ND)
- 409 A
- 50% ED Rated Output Current
- x No
- Overload Tolerance (ND)
- 120 % for 60 s
- Overload Tolerance (HD)
- 150 % for 60 s
- Max. applicable motor power (HD)
- x No
- Max. applicable motor power (ND)
- 220 kW
- Input power phases
- 3-phase
- EMC filter
- x No
- Motor type
- x No
- Encoder
- x No
- Standards compliance
- CE, UL, UKCA
- Regenerative Capacity
- x No
- Ambient Temperature (Min)
- -10 °C
- Ambient Temperature (Max)
- 40 °C
- Ambient Temperature (Max) with Derating
- 50 °C
- Max. Humidity (non-condensing)
- 95 %
- Max. Altitude (without Derating)
- 1000 m
- Max. Altitude (with Derating)
- 3000 m
- Height
- 1140 mm
- Width
- 370 mm
- Depth
- 370 mm
- Weight
- 183 kg
- Cooling method
- Air cooling
- Enclosure
- IP00
- Environmental Specifications
- Standard
- Analog Input
- 3
- Analog Output
- 2
- Digital Input
- 8
- Digital Output
- 4
- Safety Level
- x No
- Performance Level
- x No
- Torque Control
- Not available
- Braking transistor
- External
- Motor Thermal Protection
- Not available
- Max Output Frequency
- x No
Downloads
Name | |||
D1000 Regenerative Converter Unit
Brochure No. YEU_Inv_D1000_EN_V6 Brochures | English |
Brochures | English | |
D1000 Regenerative Converter Unit
Brochure No. YEU_Inv_D1000_DE_V6 Brochures | German |
Brochures | German | |
D1000 Regenerative Converter Unit
Brochure No. YEU_Inv_D1000_IT_v3 Brochures | Italian |
Brochures | Italian | |
D1000 Regenerative Converter Unit
Brochure No. YEU_Inv_D1000_PL_v3 Brochures | Polish |
Brochures | Polish | |
D1000 | Technical Manual
SIEP-C710656-06F Technical documentation | English |
Technical documentation | English | |
D1000 | Quick Start Guide
TOEP-C710656-06E Technical documentation | English |
Technical documentation | English | |
D1000 AC Drives | EU Declaration of Conformity
Regenerative Converter D1000 & 3ph Input Harmonics Filter Module, Low Voltage Directive, Electromagnetic Compatibility Directive, RoHS, Certificate No. EZZ024666<0> issued Mar 30, 2023 Certification | Czech, Danish, Dutch, English, Finnish, French, German, Italian, Polish, Slovenian, Spanish, Swedish |
Certification | Czech, Danish, Dutch, English, Finnish, French, German, Italian, Polish, Slovenian, Spanish, Swedish | |
Yaskawa AC Drives UL Certificate
Power Conversion Equipment, AC Drives 7-Series, 1000 Series, GA Series including Options, Cert. No. NMMS.E131457 Certification | English |
Certification | English | |
Epcos D1000 CE Declaration of Conformity
Low Voltage Directive 2006/95/EC EN 61558-2-20:2011; applicable for D1000 kits D1KIT40005AAAAB with B84143G0008R176, D1KIT40010AAAAB with B84143G0016R176, D1KIT40020AAAAB with B84143G0030R176, D1KIT40030AAAAB with B84143G0043R176, D1KIT40040AAAAB with B84143G0058R176, D1KIT40060AAAAB with B84143G0086R176, D1KIT40100AAAAB with B84143G0145R176, D1KIT40130AAAAB with B84143G0210S176, D1KIT40185AAAAB with B84143G0300S176, D1KIT40270AAAAB with B84143G0410S176, D1KIT40370AAAAB with B84143G0560S176, D1KIT40630AAAAB with B84143G1140S176 Certification | English |
Certification | English | |
CAD for Regenerative Converter D1000 [DC2A0005BAA]
CIMR-DC2A0005BAA, 200V 5kW, Data package CAD/CAE | |
CAD/CAE | ||
CAD for Regenerative Converter D1000 [DC2A0010BAA]
CIMR-DC2A0010BAA, 200V 10kW, Data package CAD/CAE | |
CAD/CAE | ||
CAD for Regenerative Converter D1000 [DC2A0020BAA]
CIMR-DC2A0020BAA, 200V 20kW, Data package CAD/CAE | |
CAD/CAE | ||
CAD for Regenerative Converter D1000 [DC2A0030AAA]
CIMR-DC2A0030AAA, 200V 30kW, Data Package CAD/CAE | |
CAD/CAE | ||
CAD for Regenerative Converter D1000 [DC2A0050AAA]
CIMR-DC2A0050AAA, 200V 50kW, Data package CAD/CAE | |
CAD/CAE | ||
CAD for Regenerative Converter D1000 [DC2A0065AAA]
CIMR-DC2A0065AAA, 200V 65kW, Data package CAD/CAE | |
CAD/CAE | ||
CAD for Regenerative Converter D1000 [DC2A0090AAA]
CIMR-DC2A0090AAA, 200V 90kW, Data package CAD/CAE | |
CAD/CAE | ||
CAD for Regenerative Converter D1000 [DC2A0130AAA]
CIMR-DC2A0130AAA, 200V 130kW, Data package CAD/CAE | |
CAD/CAE | ||
CAD for Regenerative Converter D1000 [DC4A0005BAA]
CIMR-DC4A0005BAA, 400V 5kW, Data package CAD/CAE | |
CAD/CAE | ||
CAD for Regenerative Converter D1000 [DC4A0010BAA]
CIMR-DC4A0010BAA, 400V 10kW, Data package CAD/CAE | |
CAD/CAE | ||
CAD for Regenerative Converter D1000 [DC4A0020BAA]
CIMR-DC4A0020BAA, 400V 20kW, Data package CAD/CAE | |
CAD/CAE | ||
CAD for Regenerative Converter D1000 [DC4A0030AAA]
CIMR-DC4A0030AAA, 400V 30kW, Data package CAD/CAE | |
CAD/CAE | ||
CAD for Regenerative Converter D1000 [DC4A0040AAA]
CIMR-DC4A0040AAA, 400V 40kW, Data package CAD/CAE | |
CAD/CAE | ||
CAD for Regenerative Converter D1000 [DC4A0060AAA]
CIMR-DC4A0060AAA, 400V 40kW, Data package CAD/CAE | |
CAD/CAE | ||
CAD for Regenerative Converter D1000 [DC4A0100AAA]
CIMR-DC4A0100AAA, 400V 100kW, Data package CAD/CAE | |
CAD/CAE | ||
CAD for Regenerative Converter D1000 [DC4A0130AAA]
CIMR-DC4A0130AAA, 400V 130kW, Data package CAD/CAE | |
CAD/CAE | ||
CAD for Regenerative Converter D1000 [DC4A0185AAA]
CIMR-DC4A0185AAA, 400V 185kW, Data package CAD/CAE | |
CAD/CAE | ||
CAD for Regenerative Converter D1000 [DC4A0270AAA]
CIMR-DC4A0270AAA, 400V 270kW, Data package CAD/CAE | |
CAD/CAE | ||
CAD for Regenerative Converter D1000 [DC4A0370AAA]
CIMR-DC4A0370AAA, 400V 370kW, Data package CAD/CAE | |
CAD/CAE | ||
CAD for Regenerative Converter D1000 [DC4A0630AAA]
CIMR-DC4A0630AAA, 400V 630kW, Data package CAD/CAE | |
CAD/CAE | ||
EPLAN for Regenerative Converter D1000 with EMC Filter
EPLAN Makros for D1000 Models with EMC Filter EPLAN | English |
EPLAN | English | |
EPLAN for Regenerative Converter D1000 without EMC Filter
EPLAN Makros for D1000 Models without EMC Filter EPLAN | English |
EPLAN | English | |
Installation guide 8A 58A
Installation Guide for LCL Filter Type B84143G0008R176 (D1000 Converter Type CIMR-Dx4A0005xxx); Type B84143G0016R176 (D1000 Converter Type CIMR-Dx4A0010xxx); Type B84143G0030R176 (D1000 Converter Type CIMR-Dx4A0020xxx); Type B84143G0043R176 (D1000 Converter Type CIMR-Dx4A0030xxx); Type B84143G0058R176 (D1000 Converter Type CIMR-Dx4A0040xxx) Technical documentation | English |
Technical documentation | English | |
Installation guide 86A 145A
Installation Guide for LCL Filter Type B84143G0086R176 (D1000 Converter Type CIMR-Dx4A0060xxx) and LCL Filter Type B84143G0145R176 (D1000 Converter Type CIMR-Dx4A0100xxx) Technical documentation | English |
Technical documentation | English | |
Installation guide 210A 300A
Installation Guide for LCL Filter Type B84143G0210S176 (D1000 Converter Type CIMR-Dx4A0130xxx) and LCL Filter Type B84143G0300S176 (D1000 Converter Type CIMR-Dx4A0185xxx) Technical documentation | English |
Technical documentation | English | |
Installation guide 410A-3
Installation Guide for LCL Filter Type B84143G0410S176 (D1000 Converter Type CIMR-Dx4A0270xxx) Technical documentation | English |
Technical documentation | English | |
Installation guide 560A-51-1
Installation Guide for LCL Filter Type B84143G0560S176 (D1000 Converter Type CIMR-Dx4A0370xxx) Technical documentation | English |
Technical documentation | English | |
Installation guide 1140A-51-1
Installation Guide for LCL Filter Type B84143G1140S176 (D1000 Converter Type CIMR-Dx4A0630xxx) Technical documentation | English |
Technical documentation | English | |
D1000 EMC Filter Datasheet | Series B84143A*R106
3-line filters of series B84143A*R106 Doc. No. B84143A0020R106-0100R106 Data sheet | English |
Data sheet | English | |
D1000 EMC Filter Datasheet | Series B84143B*S080, S081
3-line filters of series B84143B*S080, S081 Doc. No. B84143B0180S080-1600S080 Data sheet | English |
Data sheet | English | |
D1000 Datasheet LCL Filter
Datasheet B84143G/Q*R/S176-07-7659; applicable for D1000 kits D1KIT40005AAAAB with B84143G0008R176, D1KIT40010AAAAB with B84143G0016R176, D1KIT40020AAAAB with B84143G0030R176, D1KIT40030AAAAB with B84143G0043R176, D1KIT40040AAAAB with B84143G0058R176, D1KIT40060AAAAB with B84143G0086R176, D1KIT40100AAAAB with B84143G0145R176, D1KIT40130AAAAB with B84143G0210S176, D1KIT40185AAAAB with B84143G0300S176, D1KIT40270AAAAB with B84143G0410S176, D1KIT40370AAAAB with B84143G0560S176, D1KIT40630AAAAB with B84143G1140S176 Data sheet | English |
Data sheet | English | |
CAD for D1000 Harmonic Filters | Model: B84143G0008R176
Harmonic Filter (Model: B84143G0008R176) with optional IP20 Cover (Model B84143Q0008R176) for Regenerative Converter Unit D1000 (Model: CIMR-DC4A0005BAA) CAD/CAE | |
CAD/CAE | ||
CAD for D1000 Harmonic Filters | Model: B84143G0016R176
Harmonic Filter (Model: B84143G0016R176) with optional IP20 Cover (Model B84143Q0016R176) for Regenerative Converter Unit D1000 (Model: CIMR-DC4A0010BAA) CAD/CAE | |
CAD/CAE | ||
CAD for D1000 Harmonic Filters | Model: B84143G0030R176
Harmonic Filter (Model: B84143G0030R176) with optional IP20 Cover (Model B84143Q0030R176) for Regenerative Converter Unit D1000 (Model: CIMR-DC4A0020BAA) CAD/CAE | |
CAD/CAE | ||
CAD for D1000 Harmonic Filters | Model: B84143G0438R176
Harmonic Filter (Model: B84143G0438R176) with optional IP20 Cover (Model B84143Q0043R176) for Regenerative Converter Unit D1000 (Model: CIMR-DC4A0030AAA) CAD/CAE | |
CAD/CAE | ||
CAD for D1000 Harmonic Filters | Model: B84143G0058R176
Harmonic Filter (Model: B84143G0058R176) with optional IP20 Cover (Model B84143Q0058R176) for Regenerative Converter Unit D1000 (Model: CIMR-DC4A0040AAA) CAD/CAE | |
CAD/CAE | ||
CAD for D1000 Harmonic Filters | Model: B84143G0086R176
Harmonic Filter (Model: B84143G0086R176) for Regenerative Converter Unit D1000 (Model: CIMR-DC4A0060AAA) CAD/CAE | |
CAD/CAE | ||
CAD for D1000 Harmonic Filters | Model: B84143G0145R176
Harmonic Filter (Model: B84143G0145R176) for Regenerative Converter Unit D1000 (Model: CIMR-DC4A0100AAA) CAD/CAE | |
CAD/CAE | ||
CAD for D1000 Harmonic Filters | Model: B84143G0210S176
Harmonic Filter (Model: B84143G0210S176) for Regenerative Converter Unit D1000 (Model: CIMR-DC4A0130AAA) CAD/CAE | |
CAD/CAE | ||
CAD for D1000 Harmonic Filters | Model: B84143G0300S176
Harmonic Filter (Model: B84143G0300S176) for Regenerative Converter Unit D1000 (Model: CIMR-DC4A0185AAA) CAD/CAE | |
CAD/CAE | ||
CAD for D1000 Harmonic Filters | Model: B84143G0410S176
Harmonic Filter (Model: B84143G0410S176) for Regenerative Converter Unit D1000 (Model: CIMR-DC4A0270AAA) CAD/CAE | |
CAD/CAE | ||
CAD for D1000 Harmonic Filters | Model: B84143G0560R176
Harmonic Filter (Model: B84143G0560R176) for Regenerative Converter Unit D1000 (Model: CIMR-DC4A0370AAA) CAD/CAE | |
CAD/CAE | ||
CAD for D1000 Harmonic Filters | Model: B84143G1140S176
Harmonic Filter (Model: B84143G1140S176) for Regenerative Converter Unit D1000 (Model: CIMR-DC4A0630AAA) CAD/CAE | |
CAD/CAE | ||
D1000 AC Drives | UKCA Declaration of Conformity
EZZ024542 issued August 16, 2022 Certification | English |
Certification | English |